Skip to main content

PROJECT EXPERIENCE SECTION OF THE QSTI/QSTO

PROJECT EXPERIENCE SECTION OF THE QSTI APPLICATION - EXAMPLE  - For those persons who have taken the exam (or plan to) and are preparing their applications for submittal to the QSTI Review Committee, the project experience section may prove a little open-ended. What are “they” looking for? How much information should I include? Do “they” want a copy of a test report? First, definitely do not send in any test reports. The committee is not equipped to handle such confidential business information. What the committee does need is information about your experience and knowledge sufficient to demonstrate that you can conduct a test project successfully and produce reliable results. As a guideline for completing this element of the application, the QSTI Review Committee has provided two examples for your use. The components of these examples coincide with those outlined in the SES application form. Group II Application (example 1)  Project One  EPA Method 7  I led a projec...

Leaders Desksmart How to add New Technician Account in Leak Detection and Repair LDAR- FEMS

Add New Technician Account in Leak Detection and Repair LDAR Leaders Desksmart

Comments

Popular posts from this blog

Air Pollution Control: A Design Approach 4th Edition

  A 25-year tradition of excellence is extended in the Fourth Edition of this highly regarded text. In clear, authoritative language, the authors discuss the philosophy and procedures for the design of air pollution control systems. Their objective is twofold: to present detailed information on air pollution and its control, and to provide formal design training for engineering students. New to this edition is a comprehensive chapter on carbon dioxide control, perhaps the most critical emerging issue in the field. Emphasis is on methods to reduce carbon dioxide emissions and the technologies for carbon capture and sequestration. An expanded discussion of control technologies for coal-fired power plants includes details on the capture of NOx and mercury emissions. All chapters have been revised to reflect the most recent information on U.S. air quality trends and standards. Moreover, where available, equations for equipment cost estimation have been updated to the present time. Abun...

How To Calibration Toxic Vapor Analyzer 1000B?

TVA1000B Quick Start and Calibration Guide 1. Install filled hydrogen tank, attach probe/readout assembly, turn on analyzer and hydrogen supply valve. 2. Wait 4-5 minutes for proper hydrogen flow, then press 1 = Run. The unit will ignite and display readings. If flame out message appears, clear the message (press Exit), wait another minute and repeat step 2. If the unit has not been properly calibrated, a bad calibration parameter error appears – go to step 3 below. 3. Press Exit until the Main Menu appears. Calibration can now be performed. For best results, allow unit to warm up for 20 minutes, then press 2 = Setup. 4. Press 1 = Calib. 5. Press 2 = SpanConc. 6. Select the detector that the span concentration is for, then press the ↑ or ↓ arrow to select the correct unit of measure for the span gas. Enter the span calibration value, and press the Enter key. Repeat steps 5 & 6 for the second detector. Typically, the calibration gases are methane (FID) and isobutylene...